Video thumbnail

DIGITAL SOLUTIONS

DT2485 DT-Bus Data Logger

The DT2485 enables low cost, stand alone, and radio-linked data collection of In-Place Inclinometer Strings and other digital bus (DT-BUS) sensors.

RST Instruments logo

Overview

DT-BUS sensors/instruments can be incorporated into a wireless, or stand alone, data collection system by using the DT2485 Data Logger. The DT2485 provides wireless transmission of data collected from the DT-BUS sensors to an RSTAR Hub in a fixed location, or to a portable hub in a DT LINK System. More information on the RSTAR and DT LINK wireless data collection options can be found by viewing their separate brochures at rstinstruments.com.

DT-BUS instruments feature a single cable running the length of an entire chain of connected sensors/instruments, which are all individually addressable. As a result, DT-BUS simplifies installation and minimizes costs by eliminating the need of a separate cable for each sensor and also reduces the amount of cable to be managed during installation. The DT2485 also supports MODBUS sensors.

The DT2485 Data Logger can also be used with DT-BUS sensors where wireless data collection is not required. A string of up to 56 biaxial DT-BUS sensors can be read by the DT2485. The DT2485 can also be upgraded with an optional radio kit and antenna to incorporate it into an RSTAR, RSTAR Affinity, or DT LINK wireless system (see separate brochures)

Product Features

  • Option for radio and antenna kit for incorporation into a RSTAR or DT LINK system
  • Battery powered for remote sites
  • Weather resistant NEMA 4X (IP66) enclosure
  • User friendly Windows® host software included at no additional cost
  • Compatible with most spreadsheet softwares

Benefits

Data insights

Data insights

Ease of use

Ease of use

Improve safety

Improve safety

Features and benefits

DT2485: DT-BUS Data Logger specifications

ItemSpecification
Memory RecordsUp to 32,000 records; maximum of 56 sensors (*Note: The DT2485 has a total of 170 channels available; however, each biaxial in-place inclinometer sensor occupies 3 channels: A, B, and temperature).
Power SourceLithium standard cell battery
Battery Life1-2 years with 10 sensors
6-7 months with 30 sensors
(NOTE: above specs based on 1 hour reading frequency and dependent on temperature and use)
ResolutionDependent on connected sensor type
CommunicationUSB Type B connector (radio optional)
Dimensions190 x 75 x 55 mm (7.48 x. 2.95 x 2.17 in.)
Temperature Range-40°C to 60°C (-40° to 140°F)
EnclosureNEMA 4X (IP66)
  

Memory specifications

ItemSpecification
Memory Size4MB
Data Transfer4,000 data points per second
Interval ModeBiaxial Node: 3 seconds, Uniaxial Node: 2 seconds
Variable Rate Mode16 user programmable sampling rates
Time FormatMonth / day / year
Hour / minute / second
Memory Full Behaviour“Wrap around” or “fill & stop” option