Video thumbnail

DIGITAL SOLUTIONS

Total Earth Pressure Cells

Total Earth Pressure Cells are designed to measure stress acting on plane surfaces with the option of mounting ears or none, depending on installation method.

RST Instruments logo

Overview

Total Earth Pressure Cells are constructed from two circular stainless steel plates, welded together around their periphery. The annular space between these plates is filled with deaired glycol. The cell is connected via a stainless steel tube to a transducer forming a closed hydraulic system. The stress acting on the plates is then transferred to the pressure transducer assembly and may be remotely monitored using either a portable readout unit or data loggers.

RST Total Earth Pressure Cells are calibrated as a complete assembly (rather than just the sensor) to capture the calibration of the complete cell for highest quality of data.

Total Earth Pressure Cells are typically installed at interfaces between soil embankments or interconnecting concrete to help determine stresses acting on those locations to provide insight on its behavior during civil or mining construction projects.

For situations where dynamic or live readings are required, such as in rail applications, the option of using a Strain Gauge Output Total Earth Pressure Cell is preferable to enable this functionality, due to its stability at higher sampling frequencies compared with Vibrating Wire signal output which is more susceptible to vibration influences.

Product features

  • Long-term stability
  • High frequency dynamic monitoring capability
  • Stainless steel construction
  • High accuracy and sensitivity
  • Optional mounting ears available

Benefits

Data insights

Data insights

Ease of use

Ease of use

Improve safety

Improve safety

Features and benefits

Total Earth Pressure Cell Specifications

ItemModel LPTPC-VModel LPTPC-S
Transducer TypeVibrating WireSilicon Strain Gauge
Range – Standard CalibrationUp to 3.0 MPa (435 psi)Up to 3.0 MPa (435 psi)
Range – Max Available20 MPa (3000 psi)20 MPa (3000 psi)
Calibrated Accuracy0.15% F.S.0.15% F.S.
Resolution0.025% F.S. minimumInfinite
Excitation Voltage5 V sq. WaveDependent on sensor
Signal Output1200 – 3550 HZ4-20 mA
0-5 VDC
0-10 VDC
4-20 mA + RS485
0-5 VDC + RS485
ThermistorYes (standard)Optional (can be added)
Conductor4 X #22 (2 for VW, 2 for Thermistor)4 X #22 | 2 X #22
Operating Temperature-20 °C to +80 °C / -4°F to +176°F-20 °C to +80 °C / -4°F to +176°F

Industries

Icon image

Civil infrastructure

Icon image

Energy

Icon image

Surface metal

Icon image

Underground mining

Contact an expert

Whether you need support, want to request a quote or simply want to learn more, reach out to our Geosolutions team. We’re here to help.